Torrent trovati per diabolik - (max 40) usate la Ricerca Avanzata per piu' risultati. Digimon ps2 iso. Diabolik The Original Sin PAL MULTi6 PS2DVD-Start2 (ESP,ENG,FRE,ITA,GER,NET) Titolo: Diabolik - The Original Sin Tipologia prodotto: VIDEOGAME Produttore: Black Bean Genere: Avventura Console: PlayStation 2 Descrizione.

TELYS also has a built-in fault finding tool for fault or alarm diagnosis. TELYS is fitted as standard on the PW V series of generators, but can be easily fitted in place of the NEXYS to provide enhanced capability to the PW T and J series generators. Key Benefits – TELYS. Dragon age nude mod. Advanced control panel for manual and automatic generator control.

TelysMics
POWER PRODUCTS 50Hz 7,5 kVA -550 kVA
ENGLISH
PPR50/GB-2004/1
standard & 3
POWER PRODUCTS
50HZ
1
2
(delivered loose)
9
9 dB (A) residential silencer and flexible
Air-filter with replacable cartridge
4
6
Automatic fuel fill kit for frame tank
Silencer 29 dB (A) supplied separately
5 10 Protection mesh for fan and revolving parts
8
Heat hand protection
Retention bund on DT
11
7
W separator fuel prefilter
Technical documentation level B
8
Fuel inlet/return connections (no tank)
optional equipment EQUIPMENTS PACIFIC
Miscellaneous
Gas
Fuel
Starting
Cooling
Exhaust
Oil
Genset
Alternator
Motor
Standard and Options
TN 15/20 TM 7,5/11,5
● 4-stroke liquid-cooled diesel engine X 4-stroke liquid-cooled gas engine ● Mechanical governor X Electronic governor ● Standard air-filter 1 X Air filter with replacable cartridge EN 20 Coolant heater 220/240 V (without relay) X Coolant heater 120 V with thermostat X IP 21 single-bearing alternator class H insulation ● IP 23 single-bearing alternator class H insulation X Anti condensation heater X Tropical impregnation X Synchronizing C.T. + 3 fonction regulator X PMG + Regulator ● Electric panel compliance CEL 03 Compliance with CSA NRTL/C ● Output breaker ● Fabricated all welded baseplate with anti-vibration mountings ● Standard colour RAL9005/5007 (black/blue) delivered in shrinkwrap ● Supplied with oil and coolant (-30°C) ● Lub oil drain valve + diesel oil or gas flexible X Lub oil drain pump 2 ● Silencer 9 dB(A) supplied separately EN 07 Silencer 9 dB(A) not supplied EN 12 Silencer 9 dB(A) adjustable (not compatible with CEL 02) 4 EN 08 Silencer 29 dB(A) supplied separately EN 09 Silencer 40 dB(A) supplied separately EN 13 40 cm extension 3 EN 10 Exhaust outlet with flexible and flanges or flexible 5 CEL 02 Heat hand protection (“CE” requirement) ● Mounted radiator for “air on” temp. 50°C (depending on version) with drain cock FD 11 Delivered without coolant 6 ● Protection mesh for fan and revolving parts EN 14 Front rad protection 12 V Starter and charge alternator ● Battery with cables and battery tray EN 15 Non-supply of batteries and tray (cables still supplied) EN 16 Battery isolator ● Inbuilt fuel tank FD 01 7 Fuel inlet/return connections (no tank) X 9 Automatic fuel fill kit for frame tank FD 08 Automatic fuel fill kit for separate tank X 10 Retention bund on DT FD 05 W separator fuel prefilter 8 FD 06 Tank with retention bund FD 14 Retention bund alarm for separate tank(5) X Gas pressure regulator X Solenoid valve X Rigid gas link X Flexible link with crimpled nozzle X Connection with 1/4 turn 3/4' valve X Natural gas adjustment X LPG adjustment ● Multilingual(7) technical documentation level A(6) (extra copy) AD 12 German version AD 21 Multilingual(7) technical documentation level A(6) (extra copy) AD 22 German version level A (extra copy) 11 AD 31 English version level B(8) AD 41 English version level C(9) AD 05 Standard tool set AD 06 Standard tool box O GENSERVICE spare parts
TM 16/20
JM 30 JM 40


X
X
MONTANA JS 60 JS 120 JS 70 JS 150 JS 80 JS 180 JS 100 JS 275 ● ●
X
X




EN 01(1)
EN 01
EN 01
EN 01
NEVADA JS 200 JS 350 JS 400
ATLANTIC


X
X
X X
X X


X
X
● ●
● ●
● ●
● ●
EN 02 EN 20 X
EN 02 EN 20 X X
X EN 20 X
X EN 20 EN 21 X




EN 02 EN 20 X X
EN 02 EN 20 X
EN 02 EN 20 X X
EN 02 EN 20 X X


● ●
AL 01 AL 05 X AL 06
AL 01 AL 05 O(3) AL 06
AL 01 AL 05 O AL 06

● ●(2)
X X X X
X X X X
KM 25 KM 40

● ●(2)
AL 01 AL 05 O AL 06
X X X X
KS 60 KS 85 KS 100

AL 01 AL 05 X AL 06








CEL 03
CEL 03
CEL 03
CEL 03
CEL 03
CEL 03
CEL 03
CEL 03
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
EN 04
EN 04
EN 04
EN 04
EN 05
EN 05
EN 05
EN 05








EN 07 EN 12 EN 08 EN 09 EN 13 EN 10 CEL 02
EN 07 EN 12 EN 08 EN 09 EN 13 EN 10 CEL 02
EN 07 EN 12 EN 08 EN 09 EN 13 EN 10 CEL 02
EN 07 EN 12(4) EN 08 EN 09 EN 13(4) O CEL 02
EN 07 X EN 08 EN 09 X O CEL 02
EN 07 X EN 08 EN 09 X EN 11 CEL 02
EN 07 X EN 08 EN 09 X EN 10 CEL 02
EN 07 X EN 08 EN 09 X EN 10 CEL 02








FD 11
FD 11
FD 11
FD 11
FD 11
FD 11
FD 11
FD 11








EN 14 12 V
EN 14 12 V
EN 14 12 V
EN 14 12 V
EN 14 24 V(10)
EN 14 24 V
EN 14 12 V
EN 14 12 V








EN 15 EN 16
EN 15 EN 16
EN 15 EN 16
EN 15 EN 16
EN 15 EN 16
EN 15 EN 16
EN 15 EN 16 X X X X X X X X
EN 15 EN 16 X X X X X X X X






FD 01 X FD 08 FD 04 FD 05 FD 06 FD 14 X X X X X X X
FD 01 X O FD 04 FD 05 FD 06 FD 14 X X X X X X X
FD 01 FD 15 O FD 05 FD 06 FD 14 X X X X X X X
FD 01 FD 15 O FD 04 FD 05 O FD 14 X X X X X X X
FD 01 FD 15 O FD 04 FD 05 O FD 14 X X X X X X X
FD 01 FD 15 O FD 04 FD 05 O FD 14 X X X X X X X
● ● ● ● ● ●
● ● ● ● ● ●
CEL 05
CEL 05








AD 12 AD 21 AD 22 AD 31 AD 41 AD 05 AD 06 O
AD 12 AD 21 AD 22 AD 31 AD 41 AD 05 AD 06 O
AD 12 AD 21 AD 22 AD 31 AD 41 AD 05 AD 06 O
AD 12 AD 21 AD 22 AD 31 AD 41 AD 05 AD 06 O
AD 12 AD 21 AD 22 AD 31 AD 41 AD 05 AD 06 O
AD 12 AD 21 AD 22 AD 31 AD 41 AD 05 AD 06 O
X AD 21 X AD 31 AD 41 X X X
X AD 21 X AD 31 AD 41 X X X

● Standard X Impossible O Different options available - Contact us EN 01 Option code EN 01 Free option (1) Impossible on TM 16 (2) Not available on JM 40 and KM 40 (3) Only on JS 180 and JS 275 (4) Not available on JS 275 (5) Select Telys Mics fitted with CB 12 Master Card (6) Level A documentation including : Maintenance manual and diagrams + genset user manual and description of switchboard + genset installation guide (7) French, english, spanish (8) Level B including : level A + list of engines and alternator parts (english only) (9) Level C including : Level B + workshop manual (english only) (10) 12 V for JS 200.
9
canopies POWER PRODUCTS
50HZ
Discover our modular hood concept and transparently appreciate its advantages ! In addition to noise reduction, this particularly economical concept enables you to optimise your generator set’s footprint and to benefit from features such as easy handling, a backing plate, a catch tray …
CANOPY 227
CANOPY 126
CANOPY 226
10
CANOPY 107
CANOPY 128
CANOPY 228
CANOPY 129
CANOPY 229
GENSETS & CANOPIES 3 - PHASE Type
PACIFIC
MONTANA
NEVADA
ATLANTIC
Canopy
TN15 SK TN 20 SK TN 27 SK TM 7,5 K TM 11,5 K TM 16 K TM 20 K JM 30 JM 40 K JS 60 K JS 70 K JS 80 K JS 100 K JS 120 K JS 150 K JS 180 K JS 200 K JS 275 K JS 350 K JS 400 K KM 25 G KM 40 G KS 60 G KS 85 G KS 100 G GS 200 K GS 250 K GS 300 K GS 375 K GS 400 K GS 450 K GS 500 K
126 126 126 126 126 126 107 107 107 128 128 128 129 226 226 226 226 227 228 228 107 128 129 129 129 227 227 228 228 228 229 229
Type
Canopy
Tank (L) 50 50 50 50 50 50 100 100 100 180 180 180 190 340 340 340 340 390 470 470 390 390 470 470 470 500 500
Dimensions L x w x h (m) 1,75x0,72x1,23 1,75x0,72x1,23 1,75x0,72x1,23 1,75x0,72x1,23 1,75x0,72x1,23 1,75x0,72x1,23 2,10x0,92x1,45 2,10x0,92x1,45 2,10x0,92x1,45 2,30x1,08x1,68 2,30x1,08x1,68 2,30x1,08x1,68 2,55x1,17x1,68 3,51x1,20x1,83 3,51x1,20x1,83 3,51x1,20x1,83 3,51x1,20x1,83 4,00x1,38x2,13 4,48x1,41x2,43 4,48x1,41x2,43 2,10x0,92x1,45 2,30x1,08x1,68 2,55x1,17x1,68 2,55x1,17x1,68 2,55x1,17x1,68 4,00x1,38x2,13 4,00x1,38x2,13 4,48x1,41x2,43 4,48x1,41x2,43 4,48x1,41x2,43 5,03x1,56x2,43 5,03x1,56x2,43
Weight (1) (kg) 535 534 798 455 535 575 845 1035 1115 1490 1530 1530 1820 2020 2110 2200 2364 3215 4170 4170 957 1030 1240 1400 1400 3050 3200 3980 4320 4320 4660 4725
LWA 96 96 96,7 86 86,1 86,5 88 95 91,1 96,4 96,4 96,4 94,5 96,1 96,1 96,6 96,6 98,2 95,5 95,6 87 95,5 95,7 96,2 97,3 94,5 97,8 98,6 98,8 98,8 99,3 99,3
Acoustic power - 50 Hz dB(A)@1m dB(A)@7m 80,8 70,8 78,4 68,4 81 71 70,1 60,1 70,4 60,4 70,7 60,7 71,6 61 78,4 68 74,8 65 79,5 70 79,5 70 79,5 70 77 67 78,1 68 78,6 68,8 78,6 68,8 78,6 68,8 79,5 69,5 76,2 66,5 76,3 66,6 70,7 61 78,6 68,6 78,5 68,5 78,1 68 79,2 69,2 75,7 65,7 79 69 79,4 70 79,5 69,5 79,2 69,2 79,7 69,7 79,7 69,7
Tank (L) 50 50 50 50 100 -
Dimensions L x w x h (m) 1,75x0,72x1,23 1,75x0,72x1,23 1,75x0,72x1,23 1,75x0,72x1,23 2,10x0,92x1,45 2,10x0,92x1,45
Weight(1) (kg) 466 455 565 600 845 1023
LWA 96 86 86,1 86,5 89,7 87
Acoustic power - 50 Hz dB(A)@1m dB(A)@7m 80,8 70,8 70,1 60,1 70,4 60,4 70,7 60,7 73,5 64 70,7 61
1 - PHASE
PACIFIC
NEVADA
TN 15 SKM TM 7,5 KM TM 11,5 KM TM 16 KM TM 20 KM KM 25 GM
126 126 126 126 107 107
(1) Dry weight without fuel
EQUIPMENT STANDARD AND OPTIONS
Canopy
Lifting
Safety
Easy maintenance access
Trailers
Mounted soundproof canopy Soundproofed canopy kit(1) Colour Black/Blue (RAL 9005/RAL 5007) Black and specific colour (Caution delay : 8 weeks min) Modular sheet steel structure Phosphate priming followed by anti-corrosion polyester powder coat Flexible seals between body sections Central lifting eye (Lifting points) Baseplate with retention tank Simple baseplate Lockable doors with single key Lockable control panel Exterior emergency stop button Access to fuel, oil and battery through lockable doors Protective mesh for rotating parts Silencer inside canopy Galvanised sheet metal air outlet duct Sockets panel (400 V Tri + N) Doors on each side (No of doors) Lub oil drain pump Electric panel door Road Trailer for soundproofed canopy Eye 40 mm (DIN German) Eye 68 mm (French) Eye 76 mm (NATO) Ball 50 mm (Universal) Spare wheel kit jack
107
126 128 129
226
227 228 229
SiM SiK ● CN 08 ● ● ● 1 ●(3) X ● ● ● ● ● ● X CN 04 1+1 EN 04 ● TR 11(3) TR 21 ● TR 25 TR 26 TR 31
SiM X(2) ● CN 08 ● ● ● 1 ●(3) X ● ● ● ● ● ● CN 03 CN 04 2+1 EN 04 ● TR 11(3) TR 21 ● TR 25 TR 26 TR 31
SiM X ● CN 08 ● ● ● 1 FD 04 CN 05 ● ● ● ● ● ● CN 03 X 3+1 EN 04 ● TR 11 TR 21 ● TR 25 TR 26 TR 31
SiM X ● CN 08 ● ● ● 2 FD 04 CN 05 ● ● ● ● ● ● CN 03 X 2+2 EN 04 ● X X X X X X
● Standard X Impossible CN 04 Option code CN 04 Free option (1) Assembly by authorised SDMO personnel only (2) Option Sik for the canopy 126 (3) Impossible on NEVADA gensets
11
POWER PRODUCTS
50HZ
electrical panels CONTROL PANELS NEXYS Pacific ● Montana (JM 30 to JS 275K) ● Montana (JS 350K to JS 400K) X Atlantic X Nevada ●
TELYS
KERYS
O
X
O
O(1)

O

O
O
X
(1) consult us
NEW
MICS NEXYS PRESENTATION
The Mics NEXYS, SDMO’s new entry level unit, can run in automatic or manual modes. Modular in design, it offers high quality basic functions for the simplified and reliable control of your generator set. Board lighting Emergency stop button
Indicator LEDs
ON/OFF keyed switch LCD display
Safety fuse Scroll display button Generator stop button Generator start button
Position of options
Safety devices
O O O ● LCD O ● LCD ● LCD ● LCD ● ● O O ● ● ● ● ● ● ● ● ● ●
Automation
Line voltages in Volts Single voltages in Volts Phase currents in Amps Frequency in Hertz Analogical indicator Indication of engine speed Indication of battery voltage Elapsed hour meter Fuel solenoid-operated valve control Starter control Plug preheating control Water preheating control Oil pressure fault Water temperature fault Fail to start fault Overspeed fault Set ready for load Charging alternator fault General alarm General fault Panel lamp Emergency stop fault
Miscellaneous
Operation and/or safety lights Engine parameters Measurements
SPECIFICATIONS
0001 O 0001 LCD X
Overload or short-circuit or fault Overspeed fault Differential triggering fault Automatic standby Voltage and speed stabilization Plug preheating Mains contactor position return Generating set and mains, contactor position return
External starting order Mains sensing 3-ph Test LEDs Fault reset External AMF predisposition 3-phase with or without neutral, 2-phase or single-phase use 12V battery charger Differential protection with time and sensitivity adjustment Alarm hooter Permanent insulation controller
O ● O ● ● O X (self-controlled INS) X (self-controlled INS) O O ● ● O ●(1) O O(2) O O
Standard Option code Standard with LCD message Not available
(1) Choice is revised through programming - The alternator's voltage reference connecting wire modification is necessary (2) The earth fault protection is ensured by one external module
For more information concerning the Mics NEXYS, see the Nexys documentation (NEX/GB-2004/1) or contact your SDMO sales representative.
12
MICS
TELYS
PRESENTATION
A major component of our range of control units, the Mics TELYS is a standard addition to our generator sets from 200 kVA upwards its user-friendly interface and range of features allow careful monitoring of your installation.
1 “ON” KEY with integrated LED (after automatic extinction)
LCD SCREEN
4 electrical QUANTITIES
incorpored back-lighting, featuring 8 lines x 21 characters
AND ENGINE PARAMETERS KEYS
8 DISPLAY LEDS alarms, faults, statuses
15 PROGRAMMING KEYS
1 - Oil pressure fault (R) 2 - Water temperature fault (R) 3 - Failure to start fault (R) 4 - Overspeed fault (R) 5 - Set ready to output (G) 6 - Charging alternator fault (R) 7 - General alarm (Y) 8 - General fault (R)
NUMBER KEY PAD (0 TO 9)
4 OPERATING MODE SELECTION KEYS with integrated selection LEDs
(R = red, G = Green, Y = Yellow)
2 ERROR RESET
2 generating SET REGULATION
AND LED TEST KEYS
OUTPUT KEYS
(+/-)
0001 Standard O Option code 0001 LCD Standard with LCD message
Safety devices
● LCD ● LCD ● LCD ● LCD ● LCD ● LCD O O ● LCD ● LCD ● LCD ● ● ● O O O (3) O (3) ● ● ● ● ● ● ● ● ● ● O (3) O (3) ● LCD
Automation
Line voltages in Volts Single voltages in Volts Phase currents in Amps Neutral current in Amps Frequency in Hertz All generating set states, all starter phases Analogical indicator Ammeter battery Indication of engine speed Indication of battery voltage Elapsed hour meter Powering up Fuel solenoid-operated valve control Starter control Plug preheating control Water preheating control Mains contactor control Generating set contactor control Oil pressure fault Water temperature fault Fail to start fault Overspeed fault Set ready for load Charging alternator fault General alarm General fault Panel lamp, 22 dia. STOP/MANU/AUTO/TEST mode Generating set side contactor closed Mains side contactor closed Any faults or any alarms messages
Miscellaneous
Operation and/or safety lights
Operation
Engine Parameters
Measurements
SPECIFICATIONS Oil pressure fault Water temperature fault Emergency stop fault Overload or short-circuit alarm or fault Min/max battery voltage alarm or fault Min/max alternator voltage alarm or fault Min/max alternator frequency alarm or fault Overspeed fault Differential relay present fault Differential triggering alarm or fault Automatic standby Automatic extinction 4 modes Engine stopping for cooling Voltage and speed stabilization Plug preheating ATS changeover presence choice Mains contactor position return Generating set and mains contactor position return Generating set contactor manual closing Generating set contactor manual opening Starting on clock External starting order Mains sensing 3-ph Test LEDs Fault reset External AMF predisposition 3-phase with or without neutral, 2-phase or single-phase use 12V battery charger GES Pack(6) fitted inside the genset(7) Differential protection with time and sensitivity adjustment Alarm hooter
● ● ● ● (2) ● (2) ● (2) ● (2) ● O (3) O (2+3) ● ● ● ● ● O O (1) O (1) O (1) O (1) O (1) O (1) O (1) O (4) ● ● O ● (5) O O O (2) O
(1) Control and automatisms installed, but necessity to have the option 'External AMF predisposition' and the possible configuration of one parameter on the MICS® Telys (2) The choice Alarm or Fault is programmed through the keyboard (3) The earth fault protection is ensured by one external module connected to the CB12 card and through connecting of one tiny relay on the CB12 card. A local configuration is also needed (4) MICS DS mains detection is proposed as a base in the source inverter. In the case whereby the source inverter is not chosen, the MICS DS module can be moulded in the panel (5) Choice is revised through programming - The alternator's voltage reference connecting wire modification is necessary (6) For details, please consult us (7) NF E37312 standard
This software developed by SDMO enables the user to set up the dialog between the Mics TELYS panel fitted on our gensets and the PC type computer on which it is installed in order to control from a distance the operating system. Depending on the configuration of your installation, you can select from 4 types of connection, the one that best suits your needs : local mode supervision, Switched Telephone Network remote management, Ethernet remote management or SGM network remote management. For further information concerning Wintelys, please contact an SDMO reseller. .
13
NEW
POWER PRODUCTS
50HZ
MICS KERYS PRESENTATION
The Mics KERYS is a user-friendly and intuitive tool that possesses a very broad range of features. It is fitted as standard on all generator sets intended for coupling applications and can be fitted as an option on all of our other applications. In order to meet all of the requirements of low or high voltage power plants, the Mics KERYS can be fitted into a control desk, directly onto the generator set, or in a separate cabinet. It complies with EC, UL and CSA standards. Control keypad with display LED Manu mode selection Stop mode selection Auto mode selection Open/Close GE circuit breaker Activate/Deactivate test Open/Close network circuit breaker LED test Stop horn Erase anomalies
Display screen TFT LCD 7,4 in Colour graphical display Touch screen Dimensions 154 x 86 mm
Configuration keypad For configuration, navigation and direct access to screens
Control keypad with display LED
The Mics KERYS is available in two versions. The basic GUI (Graphical User Interface) is made up of a monochrome LCD screen and a function keypad. The top of the range Mics KERYS tactil version possesses a TFT colour touch screen. Both of these versions provides a user-friendly configuration, operation or diagnostic interface.
SPECIFICATIONS The Mics KERYS possesses all of the features of the Mics TELYS (cf. table page 13)
ADDITIONAL SPECIFICATIONS Measurements Powers (active, reactive) Power factor in the various dials Active and reactive energies Synchronism (phase, voltage and frequency deviation) Voltage and current harmonics Protective measures Overload, short-circuit Line current directive Neutral current Reverse component Voltage hold-back Thermal image Voltage max. and min. Presence and absence of voltage Frequency max. and Min. Active poxer maximum Active and reactive reverse power Homopolar current and homopolar current directive Homopolar voltage and restricted earth Vector jump, mini Z and dF/dt Synchronisation Manual and automatic Frequency and voltage equalisation
Control Speed and voltage Frequency and voltage setpoint switching Frequency and voltage setpoint adjusment Active and reactive power setpoint adjustment Active and reactive power ramp-up Active and reactive power distribution Active and reactive power lock-out Manual speed and voltage control Communication Local or remote mode On board Web site RS485 link Ethernet (local mode) and Internet (remote mode) Standard added benefits Failure troubleshooting assistance Maintenance assistance (logs, automatic Email, etc.) Electrical and mechanical parameter graphs and logs Load impact management Addition of extra logics with no external tools
Coupling A612 : Generator set without grid A622 : Generator set with INS and grid, no coupling A633 : Production plant without grid A634 : Production plant with grid and INS (no grid coupling) A641 : Generator set with permanent grid coupling, no INS - grid coupling + resale A642 : Generator set with permanent grid coupling, no INS - Grid coupling + 0 kW power cap on grid A651 : Generator set with fading grid coupling and INS A661 : Generator set with permanent grid coupling and INS WEB site
WEB SITE The Mics Kerys and Kerys tactil are provided as standard with an on-board web site. This site and its 60 resident screens enables you to completely check your installation (operation and setup), whatever the distance.
For further information, check the Mics KERYS documentation or contact your SDMO sales representative. Electrical variable display screen
14
POWER
MODULES (PANELS AND AIPR)
GENERAL SPECIFICATIONS Two different presentations : - up to 630A, the power modules are integrated into the panels. The cable extra flexible connections, between the panel and the alternator are fitted within one isolating cable protection. - above 630A, power modules called AIPR are separated from the control/command. These panels are fitted on the generating set frame and connected to the alternator.
Power modules mounted in panels
AIPR
AIPR RATING
POWER SECTION 3 poles Modular circuit-breaker from 10A up to 125A X Compact circuit breaker 160A and 250A ● Compact circuit breaker 400A and 630A ● ● Standard
O Option code
1250A
1600A
With a front manual command 3 poles circuit breaker, compact type 4 poles circuit breaker, compact type
● O
● O
● O
Option motorized control (*) With 3 poles circuit breaker, open type With 4 poles circuit breaker, open type
O O
O O
O O
● ● O IP207 1020 560 238
● ● O IP207 1260 665 360
● ● O IP207 1260 665 360
Others characteristics Voltage 208V-440V Bus bars Remote control terminal box (**) Protection index Dimensions : height (mm) width (mm) depth (mm)
4 poles ● O O
X Not available
(*) The motorized remote control includes : one XF coil, one MX coil, and one AC engine. (**) Only with the option motorized control.
SEPARATE
800A
● Standard
O Option code
700A
“MAINS/STANDBY” CHANGEOVERS
GENERAL SPECIFICATIONS
● Standard
INS 1000 A
INS 2500 A
INS 700 A
INS 2000 A
INS 500 A
INS 1600 A
INS 400 A
X
INS 350 A
X
INS 275 A
X
X
X
X
X C/B X
X C/B X
X C/B X
X C/B X
X C/B X
X C/B X
X C/B X
X 600 400 200
900 700 300
900 700 300
900 700 300
900 700 300
1000 800 400
1200 1200 400
X
X
X
X
X
X
X
INS 224 A
INS 200 A
INS 144 A
INS 140 A
INS 100 A
INS 90 A
2000 800 800
X
X Fuse
X Fuse
X Fuse
X Fuse
X Fuse
X 500 400 200
X 500 400 200
X 500 400 200
X 600 400 200
X 500 400 200
X 600 400 200
X 600 400 200
X 800 600 300
X
X
X
X
X
X
X
X
INS 72 A
2000 800 800
X
X Fuse
X Not available
2000 1200 500
X
X Fuse
O Option code
C/B X
X
X Fuse
X
X X
C/B X
X
X Fuse
X
X X X
X
X
X
X X
X
X
X
X X X
X
X
X X
X X
X
X
X X
X X X
X
X
INS 63 A
2 poles 3 poles 4 poles 208-440V (3-phase) 220-240V (1-phase) Changeover by contactor Changeover by motorised CB Protection of auxiliaries(1) Terminals Copper barse Height (mm) Width (mm) Depth (mm) Adjustable mains sensing relay Wall panel IP 54 Free-standing panel IP 54
INS 45 A DIMENSIONS
CONNECTIONS
VOLTAGE
SDMO supplies a full range of separate 'Mains-Standby' changeover switches. This technical solution has several advantages : cost (positioned near mains input panel), easy installation (single heavy cable run). This range is standard and always in stock. Two factors make the option very good value : IP 54 housing with easy access to cable connections and four lamps on the front panel face ; mains available, mains on load, genset available, genset on load. On the Mics NEXYS, the “Mains-standby” changeover switch is self-piloted. The MICS DS “mains detection” module is built into the panel. The panel conforms with EMC requirements.
X X X
X
(1) Protection of auxiliaries : mains power detection, panel relay, water heater, battery charger.